Please use this identifier to cite or link to this item: http://ir.futminna.edu.ng:8080/jspui/handle/123456789/11704
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYusuf, A.-
dc.contributor.authorAminulai, H. O.-
dc.contributor.authorAbdullahi, A.-
dc.contributor.authorAlhaji, B.-
dc.contributor.authorAlalade, A. I.-
dc.date.accessioned2021-07-26T15:03:18Z-
dc.date.available2021-07-26T15:03:18Z-
dc.date.issued2017-
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/11704-
dc.description.abstractThe study was carried out to investigate the level of dimensional compliance of commercially produced sandcrete blocks in Minna metropolis and also determine the compressive strength of collected block samples. One hundred and sixty (160), nine (9) inch hollow sandcrete block samples were collected from ten sandcrete block producing companies. Fine aggregate samples were collected from the hollow sandcrete block companies along with the hollow sandcrete blocks. Sieve analysis was carried out on the soil samples. Density, water absorption and dimension of the collected Sandcrete block samples were determined. Compressive strength at 7 and 14 days curing age was also determined. Results indicate that the fine aggregates used were not suitable for block making as the coefficient of uniformity of soil samples range from 0.71 􀁲 1.89 while the coefficient of curvature lie within 2.57 to 4.80 which do not conform to standard. None of the Sandcrete block production company met the required standard dimension as specified by Nigeria Industrial standard (NIS). Test results also revealed that the water abortion capacity of all collected block samples were below 12% maximum recommended by NIS except for block industry M which recorded 12.08%. The density was between 1.59 g/cm3 􀁲 5.05 g/cm3, greater than 1.5g/cm3 specified by NIS. The average compressive strength was between 0.21N/mm2 - 1.11N/mm2 at 14 days curing age which was less than 3.45 N/mm2 specified by NIS. It was recommended that block producing industries should be enforced by the standard organization of Nigeria to follow the recommended standard dimensions by carrying out routine check.en_US
dc.publisherSchool of Engineering and Engineering Technology, Federal University of Technology Minnaen_US
dc.relation.ispartofseries2nd International Engineering Conference (IEC 2017);-
dc.subjectCompressive strengthen_US
dc.subjectSandcrete blocken_US
dc.subjectsieve analysisen_US
dc.subjectwater absorptionen_US
dc.titleDimensional Compliance and Compressive Strength of Sandcrete Hollow Blocks Produced in Minna Metropolisen_US
Appears in Collections:Civil Engineering

Files in This Item:
File Description SizeFormat 
IEC2017_YUSUFpdf.pdf236.24 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.