Please use this identifier to cite or link to this item: http://ir.futminna.edu.ng:8080/jspui/handle/123456789/12963
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlhassan, D.U-
dc.contributor.authorShehu, J-
dc.date.accessioned2021-08-09T11:40:12Z-
dc.date.available2021-08-09T11:40:12Z-
dc.date.issued2018-
dc.identifier.citationShehu Jamilu, Usman D. Alhassan and Aisha Alkali (2018)en_US
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/12963-
dc.description.abstractVertical Electrical Sounding (VES) was carried out at Union Site Gidan Kwano Campus, Federal University of Technology Minna, Nigeria. The objectives is to delineate areas suitable for structural development and soil corrosivity of the study area. Schlumber electrode configuration was adopted with maximum current electrode spacing (AB/2) of 00m. The profile seperations was 100 m with inter grid pacing of 100 m. Total number of sixty (60) vertical electrical sounding (VES) Stations were covered. The interpretation was done using IP2WIN software and it revealed three distinct geologic layers. These include topsoil with resistivity values range between 11.41 and 1009 ohm-m and thickness is relatively thin and ranges between 1 and 6 m. The weathered/fractured layer has resistivity values also ranges from 11 to 963 ohm-m with thickness ranges from 1 m to 45 m which indicate high degree of weathered/ fracture and /or water saturation, The fresh basement has resistivity values that range between 12 and 2983 ohm-m. All the soundings were 3- layered and are characterized by A, H and Q curve types. Seventeen (17) VES station were delineated for high rise building having depths to fresh basement varying between 2 m to 5 m ( where consolidated basement is shallow with high resistivity value). The corrosivity ratings of the study area shows that 13% is moderately corrosive, 8% is slightly corrosive and 79% suggest practically noncorrosive. The result reasonably provide information areas where high rise building can be sited and iron pipe can be laid in order to safeguard the hydrological setting of the area.en_US
dc.description.sponsorshipSelfen_US
dc.language.isoenen_US
dc.publisherNIGERIAN JOURNAL OF PHYSICSen_US
dc.subjectVertical Electrical Soundingen_US
dc.subjectHigh riseen_US
dc.subjectresistivityen_US
dc.subjectCorrosivityen_US
dc.subjectGeologic layersen_US
dc.subjectdepthen_US
dc.titleGeoelectrical Investigation of Subsurface Structures and Soil Corrosivity at Uniors Site, Gidan Kwano Campus, Federal University of Technology, Minna, Nigeria,en_US
dc.typeArticleen_US
Appears in Collections:Applied Geophysics

Files in This Item:
File Description SizeFormat 
Jamilu et al 2018 NJP.pdf9.2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.