Please use this identifier to cite or link to this item: http://ir.futminna.edu.ng:8080/jspui/handle/123456789/17929
Title: Estimation of indoor gamma radiation dose rate from concrete blocks constructed from tin mine tailings
Authors: Olarinoye, I.O.
Kolo, Matthew Tikpangi
Shittu, H.O.
Anumah, A.S.
Keywords: Concrete block
Specific activity
Concrete Nigerian room model
Dose rate
Buildup factor
Issue Date: 2023
Publisher: Journal of Building Engineering
Abstract: The use of building materials made from geological sources contributes greatly to the indoor radiation exposure of human. As a result, it is critical for public health that building materials be screened for elevated radionuclide concentrations. This research measures the primordial radionuclide content of concrete blocks derived from mine tailings and also estimates the indoor annual effective dose rate (AEDR) and associated parameters. Furthermore, it presents a simple empirical relationship for evaluating dose rate per unit specific activity due to radionuclides from a wall of arbitrary dimensions. Twelve concrete blocks constructed using tin mine tailings as fine aggregates were collected locally and analyzed for 235U, 232Th and 40K content using gamma spectrometry analysis. The concentration of 238U ranged from 86.29 to 197.73 Bq/kg with a mean of 120.93 Bq/kg. Also, the specific activity of 232Th and 40K is within the limits: 99.01–353.67 Bq/ kg and 500.71–1021.77 Bq/kg with mean values of 248.31 Bq/kg and 635.10 Bq/kg, respectively. Obtained dose rate per unit specific activity agreed well with data from literature. Using the derived values of dose rate per unit specific activity, the annual effective dose rate (AEDR) obtained from a typical Nigerian room varies significantly from that obtained from equations in referenced documents where a different room configuration was used. The mean AEDR from the realistic Nigerian room (3.6 × 3.6 × 3 m3) was higher than the world average value but less than the recommended safety limit of 1 mSvy􀀀 1. Some of the blocks with AEDR more than the safety limits were recommended for use in superficial quantities for building construction. The model derived in this study can be applied to calculate dose rates within any room configuration.
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/17929
Appears in Collections:Physics

Files in This Item:
File Description SizeFormat 
LEKE-KOLO et al., 2023.pdf1.95 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.