Please use this identifier to cite or link to this item: http://ir.futminna.edu.ng:8080/jspui/handle/123456789/18984
Title: SEISMIC PERFORMANCE OF NEPALESE SCHOOLS: A FULL-SCALE TEST OF A TYPICAL UNREINFORCED MASONRY WALL
Authors: Aminulai, Hammed O.
Baiguera, Marco
Sextos, Anastatsios
Kashani, Mohammed M.
Issue Date: Jun-2022
Publisher: 12th National Conference on Earthquake Engineering, Earthquake Engineering Research Institute,
Abstract: This paper presents the preliminary results of an experimental investigation on the seismic performance of a large-scale typical Nepalese school URM wall. Hence, it proposes a retrofitting method for its strengthening. The test subjected a 5m x 3m masonry brick wall, set in 1:6 cement–sand mortar, to a two-way ramp cyclic loading to determine shear cracking failure. The results show that the wall exhibited a Grade 2 type of failure that indicates a slight structural damage with both diagonal and horizontal cracks, at 4mm displacement loading, in the mortar joints. The failure pattern is similar to those obtained in similar works in the literature.
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/18984
Appears in Collections:Civil Engineering

Files in This Item:
File Description SizeFormat 
1663491627_10377_Kashani.pdf1.92 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.