Please use this identifier to cite or link to this item:
http://ir.futminna.edu.ng:8080/jspui/handle/123456789/26776
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Olarinoye, I. O. | - |
dc.contributor.author | Ibrahim, Sharifat Olalonpe | - |
dc.date.accessioned | 2024-02-08T20:36:38Z | - |
dc.date.available | 2024-02-08T20:36:38Z | - |
dc.date.issued | 2010-06-01 | - |
dc.identifier.citation | Olarinoye, I. Oyeleke., Sharifat, I., (2010). A Protocol for Setting Dose Reference Level for Medical Radiography in Nigeria. Bayero Journal of Pure and Applied Science (BAJOPAS) vol 3(1) Pp138-141. | en_US |
dc.identifier.issn | 2006-6996 | - |
dc.identifier.uri | https://www.ajol.info/index.php/bajopas/article/view/58748 | - |
dc.identifier.uri | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/26776 | - |
dc.description.abstract | Patients’ dose audit reports in some Nigerian hospitals had shown large inter- and intra-hospital variations for the same radiological examinations. They have thus presented the need, to have a national standard for radiological diagnostic procedures and set dose limits for individual x-ray examination centers in Nigeria. These will go a long way in reducing inter- and intra-hospital dose range factors, thus reducing doses to as low as reasonably achievable and consistent with clinical objectives of the examinations. In establishing a national dose limit for medical radiological examinations, there is a need to have a national dose survey. This paper suggests a reasonable and easy procedure for achieving a national radiological dose survey. Due to its simplicity of measurement, the use of entrance surface dose as the dose parameter to be used for setting the dose limit as recommended by the European Union and the International Atomic Energy Agency (IAEA) is also suggested. ESD can be measured directly through the use of solid state detectors, or indirectly by measuring free air exposure which can later be converted to ESD using standard formula. The methods of measuring the entrance surface dose and how to derive the dose limit from them are also highlighted. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Bayero Journal of Pure and Applied Sciences | en_US |
dc.relation.ispartofseries | Bajopas;Volume 3 Number 1 June 2010, DOI: 10.4314/bajopas.v3i1.58748 | - |
dc.subject | medical x-ray, | en_US |
dc.subject | patients’ dose, | en_US |
dc.subject | dose limit | en_US |
dc.subject | entrance surface dose | en_US |
dc.title | A PROTOCOL FOR SETTING DOSE REFERENCE LEVEL FOR MEDICAL RADIOGRAPHY IN NIGERIA: A REVIEW | en_US |
dc.type | Article | en_US |
Appears in Collections: | Physics |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
A Protocol For Setting Dose Reference Level For Medical Radiography In Nigeria - A Review.pdf | 46.65 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.