Please use this identifier to cite or link to this item: http://ir.futminna.edu.ng:8080/jspui/handle/123456789/26873
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAuta, S. M.-
dc.contributor.authorJamiu, O.-
dc.contributor.authorAbbas, B. A-
dc.date.accessioned2024-02-27T13:36:25Z-
dc.date.available2024-02-27T13:36:25Z-
dc.date.issued2021-
dc.identifier.issnISSN 2712-8172-
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/26873-
dc.description.abstractAbstract. Modern building construction techniques sometimes involve the passing of pipes or ducts for water supply, electrification, and telecommunication through reinforced concrete beams to protect them against mechanical damages and add aesthetic value to buildings. This study looks into the effect of vertical circular openings on the flexural strength of the reinforced concrete beam. Two (2) sets of beam samples were investigated during this study: computer simulated reinforced concrete (RC) beam using ANSYS 19.1 and laboratory cast. The results of the flexural strength test conducted show the following: Reinforced concrete beam with vertical circular openings of diameter greater than 33.3 % of beam width (B) reduced its flexural strength by at least 20 %; maximum compressive stress of concrete occurs at the openings region of the beam; the difference in ultimate load capacity of finite element (FE) beam models and experimental beam specimen is 3.5 %. It can be deduced that ANSYS software is an appropriate finite element (FE) tool to predict the behaviour of RC beams. Hence, it is hereby recommended that the diameter of the vertical circular opening in RC beam should not exceed 33.3 % of the beam width and its location from beam support should not exceed L/6.en_US
dc.description.sponsorshipSelf sponsoreden_US
dc.language.isoenen_US
dc.publisherMagazine of Civil Engineeringen_US
dc.relation.ispartofseries106(6). Article No. 10601;-
dc.subjectverticalen_US
dc.subjectcircularen_US
dc.subjectopeningsen_US
dc.subjectflexuralen_US
dc.subjectstrengthen_US
dc.subjectANSYSen_US
dc.subjectbuilding.en_US
dc.titleEffect of vertical circular openings on flexural strength of reinforced concrete beamen_US
dc.typeArticleen_US
Appears in Collections:Civil Engineering

Files in This Item:
File Description SizeFormat 
4 Auta Bala and Jamihu.docx486.06 kBMicrosoft Word XMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.