Please use this identifier to cite or link to this item:
http://ir.futminna.edu.ng:8080/jspui/handle/123456789/28565
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oyetola, Emmanuel | - |
dc.contributor.author | Oritola, Sikiru | - |
dc.date.accessioned | 2024-05-20T11:16:33Z | - |
dc.date.available | 2024-05-20T11:16:33Z | - |
dc.date.issued | 2006-12-01 | - |
dc.identifier.citation | E. B. Oyetola & S. F. Oritola (2006). Investigation into the causes of electric transmission concrete poles failure. Leonardo Journal of Technology, Romania. 5:9 (July-December), p. 17-24 | en_US |
dc.identifier.uri | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/28565 | - |
dc.description | research paper | en_US |
dc.description.abstract | Abstract The major causes of electric concrete pole failures has been highlighted in this paper and possible solutions suggested. The technique involves an on-site assessment and analysis of some factors that influence the design and manufacture of concrete pole commonly used for electrification purpose. Some major manufacturers in Niger State, Kwara State and Federal Capital Territory, Abuja, Nigeria were visited and interview conducted on their method of design and manufacture of electric transmission concrete pole. Site study of some major high-tension and low-tension electrification work was also carried out. Based on observation made anomalies in concrete pole manufacture were pointed out and solution proffered. Finally concrete pole suitable for electrification purpose was designed and constructed. A rig was constructed to test the strength of the pole, thereby determining their suitability for electrification work. | en_US |
dc.description.sponsorship | Federal University of technology Minna | en_US |
dc.language.iso | en | en_US |
dc.publisher | Leonardo Journal of Technology, Romania | en_US |
dc.relation.ispartofseries | 5;9 | - |
dc.subject | Natural stone | en_US |
dc.subject | Coarse aggregate | en_US |
dc.subject | concrete pole | en_US |
dc.subject | flexural strength | en_US |
dc.subject | bending test | en_US |
dc.title | Investigation into the causes of electric transmission concrete pole failure | en_US |
dc.type | Article | en_US |
Appears in Collections: | Civil Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
017_024 Causes of Electric Transmission Concrete Pole failures.pdf | 92.73 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.