Please use this identifier to cite or link to this item: http://ir.futminna.edu.ng:8080/jspui/handle/123456789/4485
Title: Geoelectrical Prospecting for Fractured Basement Aquifer in Northern Portion of Futminna's Bosso Campus, Minna, North Central Nigeria
Authors: Unuevho, C. I.
Onuoha, K. M.
Amadi, A. N.
Alabi, A. A.
Aderogbin, J. A.
Udensi, E. E.
Oshin, O.
Keywords: Fracture Column, Groundwater Convergence Zone
Issue Date: Dec-2017
Publisher: Department of Physics, Faculty of Science, Kaduna State University, Kaduna
Abstract: Only one out of three boreholes in the northern portion of FUTMINNA's Bosso Campus is productive. Values of hydrogeophysical parameters characterising fracture column at the productive borehole site were captured from vertical electrical resistivity and spontaneous potential (SP) sounding data. The values were employed to identify other sites with potential for groundwater production in the area. Sounding locations LI, L8, L14, L19 and L20 contain fracture column characterised by 200-400?m resistivity: -10 to 20mV SP. 1200-2400?m² transverse unit resistance and 0.05-0.1?' longitudinal unit conductance. Boreholes sited at these locations would be productive because the fracture column therein has identical values of hydrogeophysical parameters with the fracture column at the productive borehole site. Sounding locations 14 and 20 were found to be groundwater convergence zones respectively within north-western and eastern portions of the investigated area. The fracture column in the vicinity of sounding location 20 is thickest and more spatially extensive, thereby making the eastern sector the most suitable for drilling productive borehole
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/4485
ISSN: ISSN 2579-1168
Appears in Collections:Geology

Files in This Item:
File Description SizeFormat 
Chris et al Bosso Campus.pdf811.08 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.