Please use this identifier to cite or link to this item:
http://ir.futminna.edu.ng:8080/jspui/handle/123456789/5714
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | David, Michael | - |
dc.contributor.author | En Marcus, Tay Ching | - |
dc.contributor.author | Yaacob, Maslina | - |
dc.contributor.author | Hussin, Nabihah | - |
dc.contributor.author | Salim, Mohd Rashidi | - |
dc.contributor.author | Ibrahim, Mohd Haniff | - |
dc.contributor.author | Idrus, Sevia Mahdaliza | - |
dc.contributor.author | Azmi, Asrul Izam | - |
dc.contributor.author | Ngajikin, Nor Hafizah | - |
dc.date.accessioned | 2021-07-01T09:24:00Z | - |
dc.date.available | 2021-07-01T09:24:00Z | - |
dc.date.issued | 2014-12-08 | - |
dc.identifier.uri | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/5714 | - |
dc.description.abstract | The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily discernible at all velocities considered; however it is more pronounced at lower flow rates. At a velocity of 16.79cm/s of ozone gas, and for a target sensing time of ≤ 0.5 seconds; we observed that the inlet radius requirements for gas cells of varying lengths and varying internal diameters is not the same for a specific target sensing speed. The length and the internal radius of a gas cell are proportional to its inlet radius | en_US |
dc.description.sponsorship | The authors would like to thank Universiti Teknologi Malaysia (UTM) for sponsoring this publication under Research University Grant (RUG) Scheme, grant no: 05J60 and 04H35; and Fundamental Research Grant Scheme (FRGS) grant no: 4F317 and 4F565. The Ministry of education (MOE) Malaysia is also acknowledge and the Nigerian Education Trust Fund (ETF) for the financial support giving inform of Tertiary Education Trust Fund (TET-Fund) | en_US |
dc.language.iso | en | en_US |
dc.publisher | 2014 IEEE Asia-Pacific Conference on Applied Electromagnetics (APACE) | en_US |
dc.subject | Optical path length; inlet diameter; internal diameter; response time; flow rate | en_US |
dc.title | Investigation of the Effect of Inlet Radius on the Response Time of a Transmission Type Ozone Sensor | en_US |
dc.type | Presentation | en_US |
Appears in Collections: | Telecommunication Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Investigation_of_the_Effect_of_Inlet_Radius.pdf | 1.69 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.