Please use this identifier to cite or link to this item:
http://ir.futminna.edu.ng:8080/jspui/handle/123456789/6241
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abdulkadir, Mukhtar | - |
dc.contributor.author | Mbalisigwe, Ugochukwu | - |
dc.contributor.author | Zhao, Donglin | - |
dc.contributor.author | Hernandez–Perez, Valente | - |
dc.contributor.author | Azzopardi, Barry | - |
dc.contributor.author | Tahir, Suleiman | - |
dc.date.accessioned | 2021-07-03T20:39:57Z | - |
dc.date.available | 2021-07-03T20:39:57Z | - |
dc.date.issued | 2019-02-01 | - |
dc.identifier.citation | 3 | en_US |
dc.identifier.issn | 03019322 | - |
dc.identifier.uri | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/6241 | - |
dc.description.abstract | This paper presents the results of a series of experimental studies conducted to investigate the characteristics of churn and annular flows in an 11 m long riser with the internal diameter of 127 mm. A series of experiments in churn–annular flow regime were performed for a range of gas superficial velocities (3.5–16.1 m/s) and liquid superficial velocities of 0.02–0.33 m/s. Statistical analysis involving average, standard deviation and skewness, dominant frequency and structure velocity of the time series data was carried out as a quantitative approach to discriminate between churn and annular flows and to describe the transition between them. The variation of average liquid film thickness against gas superficial velocity showed a minimum at gas superficial velocity of 12.4 m/s. This is in close agreement with the minima at gas superficial velocity of 13 m/s reported in the literature. The results of the comparison between average liquid film thicknesses from the conductance ring probes agree well with those obtained by using local liquid film thickness probes and conductance ring probes in the literature. The results of the comparison of dominant frequency obtained from the conductance ring probes agree well with those obtained by using wire mesh sensor (WMS) in the literature. A comparative analysis of the current experimental data with those previously published experimental results confirms good agreement. | en_US |
dc.language.iso | en | en_US |
dc.publisher | International Journal of Multiphase Flow (ELSEVIER) | en_US |
dc.subject | Churn–annular flow | en_US |
dc.subject | Entrance length | en_US |
dc.subject | Film fraction | en_US |
dc.subject | Frequency | en_US |
dc.subject | Structure velocity | en_US |
dc.subject | Waves | en_US |
dc.title | Characteristics of churn and annular flows in a large diameter vertical riser | en_US |
dc.type | Article | en_US |
Appears in Collections: | Chemical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ABDULKADIR ET AL 2019.pdf | 2.72 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.